{"product_id":"ssr-add-on-for-the-pill-by-shelly","title":"SSR Add-on for The Pill by Shelly","description":"\u003cdiv class=\"text-base my-auto mx-auto [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"69ac5608-ead0-49f1-a63b-f0c8da902130\" dir=\"auto\" data-message-model-slug=\"gpt-5-5-thinking\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal outline-none keyboard-focused:focus-ring [.text-message+\u0026amp;]:mt-1\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert wrap-break-word w-full light markdown-new-styling\"\u003e\n\u003ch2 data-start=\"41\" data-end=\"350\"\u003e\u003cstrong\u003eSSR Add-on for The Pill by Shelly | Dual-Channel DC Load Control Accessory\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-start=\"41\" data-end=\"350\"\u003eThe \u003cstrong data-start=\"45\" data-end=\"84\"\u003eDual Channel DC Load Control Add-On\u003c\/strong\u003e is designed to isolate and control two independent DC loads up to \u003cstrong data-start=\"151\" data-end=\"178\"\u003e30V \/ 300mA per channel\u003c\/strong\u003e. Using galvanically isolated solid-state relay outputs, it provides reliable low-voltage DC switching for smart control projects, automation setups, and connected devices.\u003c\/p\u003e\n\u003cp data-start=\"352\" data-end=\"615\"\u003eThis add-on is ideal for applications where two separate DC circuits need to be controlled safely and independently. It connects with \u003cstrong data-start=\"486\" data-end=\"498\"\u003eThe Pill\u003c\/strong\u003e using the required \u003cstrong data-start=\"518\" data-end=\"539\"\u003e5-Terminal Add-on\u003c\/strong\u003e, making it a compact and flexible solution for advanced DC load automation.\u003c\/p\u003e\n\u003ch3 data-start=\"617\" data-end=\"633\"\u003e\u003cstrong data-start=\"617\" data-end=\"633\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"635\" data-end=\"1057\"\u003e\n\u003cli data-section-id=\"skas\" data-start=\"635\" data-end=\"670\"\u003eControls two independent DC loads\u003c\/li\u003e\n\u003cli data-section-id=\"1bxqkkr\" data-start=\"671\" data-end=\"715\"\u003eSupports up to \u003cstrong data-start=\"688\" data-end=\"715\"\u003e30V \/ 300mA per channel\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"19mgszw\" data-start=\"716\" data-end=\"765\"\u003eGalvanically isolated solid-state relay outputs\u003c\/li\u003e\n\u003cli data-section-id=\"wf2yx9\" data-start=\"766\" data-end=\"825\"\u003e2 potential-free contact outputs: \u003cstrong data-start=\"802\" data-end=\"811\"\u003eLOAD1\u003c\/strong\u003e and \u003cstrong data-start=\"816\" data-end=\"825\"\u003eLOAD2\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ytzewd\" data-start=\"826\" data-end=\"872\"\u003e1 configurable digital input\/output: \u003cstrong data-start=\"865\" data-end=\"872\"\u003eIO3\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"13yh7hn\" data-start=\"873\" data-end=\"910\"\u003eOptional 5V and GND power terminals\u003c\/li\u003e\n\u003cli data-section-id=\"1gpju0q\" data-start=\"911\" data-end=\"933\"\u003eCompact black design\u003c\/li\u003e\n\u003cli data-section-id=\"11c6y9d\" data-start=\"934\" data-end=\"972\"\u003eLow power consumption under \u003cstrong data-start=\"964\" data-end=\"972\"\u003e0.6W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dtjx29\" data-start=\"973\" data-end=\"1009\"\u003eDesigned for use with \u003cstrong data-start=\"997\" data-end=\"1009\"\u003eThe Pill\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gpn5t6\" data-start=\"1010\" data-end=\"1057\"\u003eRequires \u003cstrong data-start=\"1021\" data-end=\"1042\"\u003e5-Terminal Add-on\u003c\/strong\u003e for connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1059\" data-end=\"1080\"\u003e\u003cstrong data-start=\"1059\" data-end=\"1080\"\u003eDevice Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1082\" data-end=\"1376\"\u003e\n\u003cli data-section-id=\"yxgwb6\" data-start=\"1082\" data-end=\"1131\"\u003e\n\u003cstrong data-start=\"1084\" data-end=\"1094\"\u003eLOAD1:\u003c\/strong\u003e Channel 1 output, max 30V DC \/ 300mA\u003c\/li\u003e\n\u003cli data-section-id=\"5vasdu\" data-start=\"1132\" data-end=\"1181\"\u003e\n\u003cstrong data-start=\"1134\" data-end=\"1144\"\u003eLOAD2:\u003c\/strong\u003e Channel 2 output, max 30V DC \/ 300mA\u003c\/li\u003e\n\u003cli data-section-id=\"1a0ufs3\" data-start=\"1182\" data-end=\"1246\"\u003e\n\u003cstrong data-start=\"1184\" data-end=\"1192\"\u003eIO3:\u003c\/strong\u003e Configurable 3.3V logic-level digital input or output\u003c\/li\u003e\n\u003cli data-section-id=\"1j8a675\" data-start=\"1247\" data-end=\"1312\"\u003e\n\u003cstrong data-start=\"1249\" data-end=\"1257\"\u003eGND:\u003c\/strong\u003e Reference ground for connected sensors or power supply\u003c\/li\u003e\n\u003cli data-section-id=\"k6f8wf\" data-start=\"1313\" data-end=\"1376\"\u003e\n\u003cstrong data-start=\"1315\" data-end=\"1322\"\u003e5V:\u003c\/strong\u003e Power output for peripherals or 5V power for The Pill\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1378\" data-end=\"1396\"\u003e\u003cstrong data-start=\"1378\" data-end=\"1396\"\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1398\" data-end=\"1614\"\u003e\n\u003cli data-section-id=\"142g5t7\" data-start=\"1398\" data-end=\"1429\"\u003eSize: 36 mm x 31 mm x 11.5 mm\u003c\/li\u003e\n\u003cli data-section-id=\"gx4x2u\" data-start=\"1430\" data-end=\"1444\"\u003eWeight: 12 g\u003c\/li\u003e\n\u003cli data-section-id=\"1kj4np9\" data-start=\"1445\" data-end=\"1460\"\u003eColour: Black\u003c\/li\u003e\n\u003cli data-section-id=\"17a1fj8\" data-start=\"1461\" data-end=\"1492\"\u003eMax switching voltage: 30V DC\u003c\/li\u003e\n\u003cli data-section-id=\"kd516q\" data-start=\"1493\" data-end=\"1523\"\u003eMax switching current: 300mA\u003c\/li\u003e\n\u003cli data-section-id=\"tu9yob\" data-start=\"1524\" data-end=\"1551\"\u003ePower consumption: \u0026lt; 0.6W\u003c\/li\u003e\n\u003cli data-section-id=\"pby1bg\" data-start=\"1552\" data-end=\"1588\"\u003eOperating temperature: 0°C to 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"a42jm6\" data-start=\"1589\" data-end=\"1614\"\u003eHumidity: 30% to 70% RH\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1616\" data-end=\"1785\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"1620\" data-end=\"1659\"\u003eDual Channel DC Load Control Add-On\u003c\/strong\u003e is a compact and practical solution for controlling low-voltage DC loads in smart automation and custom electronics projects.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Shelly","offers":[{"title":"Default Title","offer_id":47169106018475,"sku":"SH-PILLSSR","price":24.99,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2308\/2087\/files\/SSRAdd-on1.png?v=1780460783","url":"https:\/\/www.ozsmartthings.com.au\/products\/ssr-add-on-for-the-pill-by-shelly","provider":"Oz Smart Things Pty Ltd","version":"1.0","type":"link"}