{"product_id":"analog-0-30v-add-on-for-the-pill-by-shelly","title":"Analog 0–30V Add-on for The Pill by Shelly","description":"\u003ch2\u003eAnalog 0–30V Add-on for The Pill by Shelly | DC Voltage \u0026amp; Sensor Measurement Accessory\u003c\/h2\u003e\n\u003cp data-start=\"48\" data-end=\"364\"\u003eThe \u003cstrong data-start=\"52\" data-end=\"75\"\u003eAnalog 0–30V Add-on\u003c\/strong\u003e is designed to extend the voltage measuring capability of \u003cstrong data-start=\"134\" data-end=\"156\"\u003eThe Pill by Shelly\u003c\/strong\u003e, allowing it to measure analog sensors and DC voltages up to \u003cstrong data-start=\"218\" data-end=\"225\"\u003e30V\u003c\/strong\u003e. It is ideal for monitoring popular analog sensors with \u003cstrong data-start=\"282\" data-end=\"297\"\u003e0–5V output\u003c\/strong\u003e, as well as battery voltage levels such as \u003cstrong data-start=\"341\" data-end=\"363\"\u003e4.2V, 12V, and 24V\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"366\" data-end=\"597\"\u003eThis compact add-on connects to The Pill using the required \u003cstrong data-start=\"426\" data-end=\"447\"\u003e5-Terminal Add-on\u003c\/strong\u003e and provides one analog input, two configurable digital input\/output terminals, and optional 5V power terminals for connected sensors or peripherals.\u003c\/p\u003e\n\u003ch3 data-start=\"599\" data-end=\"615\"\u003e\u003cstrong data-start=\"599\" data-end=\"615\"\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"617\" data-end=\"1071\"\u003e\n\u003cli data-section-id=\"e51uc8\" data-start=\"617\" data-end=\"657\"\u003eMeasures DC voltage from \u003cstrong data-start=\"644\" data-end=\"657\"\u003e0V to 30V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"lg6d6v\" data-start=\"658\" data-end=\"710\"\u003eSuitable for analog sensors and battery monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1b5gsc\" data-start=\"711\" data-end=\"760\"\u003eSupports common sensor outputs such as \u003cstrong data-start=\"752\" data-end=\"760\"\u003e0–5V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"fmuwvk\" data-start=\"761\" data-end=\"815\"\u003eIdeal for measuring \u003cstrong data-start=\"783\" data-end=\"815\"\u003e4.2V, 12V, and 24V batteries\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vfbhgw\" data-start=\"816\" data-end=\"840\"\u003e1 analog input: \u003cstrong data-start=\"834\" data-end=\"840\"\u003eAN\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"179dfuq\" data-start=\"841\" data-end=\"900\"\u003e2 configurable digital input\/outputs: \u003cstrong data-start=\"881\" data-end=\"888\"\u003eIO2\u003c\/strong\u003e and \u003cstrong data-start=\"893\" data-end=\"900\"\u003eIO3\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"89sqej\" data-start=\"901\" data-end=\"946\"\u003eOptional \u003cstrong data-start=\"912\" data-end=\"918\"\u003e5V\u003c\/strong\u003e and \u003cstrong data-start=\"923\" data-end=\"930\"\u003eGND\u003c\/strong\u003e power terminals\u003c\/li\u003e\n\u003cli data-section-id=\"78fpls\" data-start=\"947\" data-end=\"976\"\u003eCompact black module design\u003c\/li\u003e\n\u003cli data-section-id=\"794799\" data-start=\"977\" data-end=\"1023\"\u003eDesigned for use with \u003cstrong data-start=\"1001\" data-end=\"1023\"\u003eThe Pill by Shelly\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1gpn5t6\" data-start=\"1024\" data-end=\"1071\"\u003eRequires \u003cstrong data-start=\"1035\" data-end=\"1056\"\u003e5-Terminal Add-on\u003c\/strong\u003e for connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1073\" data-end=\"1094\"\u003e\u003cstrong data-start=\"1073\" data-end=\"1094\"\u003eDevice Interfaces\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1096\" data-end=\"1429\"\u003e\n\u003cli data-section-id=\"1a0rn3q\" data-start=\"1096\" data-end=\"1173\"\u003e\n\u003cstrong data-start=\"1098\" data-end=\"1105\"\u003eAN:\u003c\/strong\u003e Analog input for measuring connected sensors or batteries, 0–30V DC\u003c\/li\u003e\n\u003cli data-section-id=\"daw51e\" data-start=\"1174\" data-end=\"1238\"\u003e\n\u003cstrong data-start=\"1176\" data-end=\"1184\"\u003eIO2:\u003c\/strong\u003e Configurable 3.3V logic-level digital input or output\u003c\/li\u003e\n\u003cli data-section-id=\"1a0ufs3\" data-start=\"1239\" data-end=\"1303\"\u003e\n\u003cstrong data-start=\"1241\" data-end=\"1249\"\u003eIO3:\u003c\/strong\u003e Configurable 3.3V logic-level digital input or output\u003c\/li\u003e\n\u003cli data-section-id=\"1j8a675\" data-start=\"1304\" data-end=\"1369\"\u003e\n\u003cstrong data-start=\"1306\" data-end=\"1314\"\u003eGND:\u003c\/strong\u003e Reference ground for connected sensors or power supply\u003c\/li\u003e\n\u003cli data-section-id=\"hx2q51\" data-start=\"1370\" data-end=\"1429\"\u003e\n\u003cstrong data-start=\"1372\" data-end=\"1379\"\u003e5V:\u003c\/strong\u003e Power output for sensors or 5V power for The Pill\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1431\" data-end=\"1449\"\u003e\u003cstrong data-start=\"1431\" data-end=\"1449\"\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1451\" data-end=\"1757\"\u003e\n\u003cli data-section-id=\"159o3x\" data-start=\"1451\" data-end=\"1486\"\u003eSize: 36.5 mm x 26.5 mm x 11.5 mm\u003c\/li\u003e\n\u003cli data-section-id=\"1xe33l9\" data-start=\"1487\" data-end=\"1500\"\u003eWeight: 8 g\u003c\/li\u003e\n\u003cli data-section-id=\"1kj4np9\" data-start=\"1501\" data-end=\"1516\"\u003eColour: Black\u003c\/li\u003e\n\u003cli data-section-id=\"1bb3w3m\" data-start=\"1517\" data-end=\"1555\"\u003eVoltage measurement range: 0V–30V DC\u003c\/li\u003e\n\u003cli data-section-id=\"3etptk\" data-start=\"1556\" data-end=\"1588\"\u003eVoltmeter accuracy: ±(2% + 5d)\u003c\/li\u003e\n\u003cli data-section-id=\"148jieo\" data-start=\"1589\" data-end=\"1622\"\u003eDigital input max voltage: 3.3V\u003c\/li\u003e\n\u003cli data-section-id=\"zgoo57\" data-start=\"1623\" data-end=\"1664\"\u003eMax switching voltage: 3.3V logic-level\u003c\/li\u003e\n\u003cli data-section-id=\"1ifejtf\" data-start=\"1665\" data-end=\"1694\"\u003eMax switching current: 20mA\u003c\/li\u003e\n\u003cli data-section-id=\"pby1bg\" data-start=\"1695\" data-end=\"1731\"\u003eOperating temperature: 0°C to 40°C\u003c\/li\u003e\n\u003cli data-section-id=\"a42jm6\" data-start=\"1732\" data-end=\"1757\"\u003eHumidity: 30% to 70% RH\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1759\" data-end=\"1950\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe \u003cstrong data-start=\"1763\" data-end=\"1809\"\u003eAnalog 0–30V Add-on for The Pill by Shelly\u003c\/strong\u003e is a practical accessory for expanding sensor and battery monitoring in smart automation, DIY electronics, and low-voltage control projects.\u003c\/p\u003e","brand":"Shelly","offers":[{"title":"Default Title","offer_id":47169132855467,"sku":"47169132855467","price":24.99,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2308\/2087\/files\/Analog0-30VAdd-on1.png?v=1780461190","url":"https:\/\/www.ozsmartthings.com.au\/products\/analog-0-30v-add-on-for-the-pill-by-shelly","provider":"Oz Smart Things Pty Ltd","version":"1.0","type":"link"}